Very high reading at Tocsin_bang 2 years 9 months ago #698

  • Tocsin_bang
  • Tocsin_bang's Avatar
  • OFFLINE
  • Senior Member
  • Posts: 40
  • Thank you received: 1
  • Karma: 1
Forgot to go offline when I did some testing. I had been cleaning the area round the tube connections with IPA, then when I switched back on it went crazy.
The administrator has disabled public write access.

Very high reading at Tocsin_bang 2 years 9 months ago #703

  • Tocsin_bang
  • Tocsin_bang's Avatar
  • OFFLINE
  • Senior Member
  • Posts: 40
  • Thank you received: 1
  • Karma: 1
There's still some kind of issue. Counts are still way too high. I need to do some work on it, trouble is my new counter isn't ready, still needs quite a bit of work done, and I have other stuff to do as well.
The administrator has disabled public write access.

Very high reading at Tocsin_bang 2 years 9 months ago #707

  • Tocsin_bang
  • Tocsin_bang's Avatar
  • OFFLINE
  • Senior Member
  • Posts: 40
  • Thank you received: 1
  • Karma: 1
Seem to have got it sorted. Two joints re-soldered, plus a good clean all round. Counter is also back in its case.